Saturn Pyro Sdn Bhd
Johor Bahru Office
44 & 44A, Jalan Palma Rafis 1,
Taman Dato Chellam,
81800 Ulu Tiram,
Johor, Malaysia.
+607-8660510
+607-8660511
enquiry@saturnpyro.com

Shah Alam Office
K03-03-12, Tower 3,
UOA Business Park,
No 1, Jalan
Pengaturcara U1/51A,
Section U1, Kawasan
Perindustrian Temasya,
40150 Shah Alam,
Selangor, Malaysia.
+607-8660510
+607-8660511
Penang Office
Penthouse 1-21-1,
Suntech @ Penang Cybercity
Lintang Mayang Pasir 3,
11950 Bayan Baru,
Penang, Malaysia.
+607-8660510
+607-8660511
desmond@saturnpyro.com

Bangalore Office
Saturnpyro Solutions Pvt. Ltd.

SFS-B-38, 1st Floor, 7th B Main Road,
Yelahanka New Town, Bangalore 560 064.
GSTIN: 29ABCCS4606C1ZK
+91 829 192 0602
+601 7488 7001
jothie@saturnpyro.com
 
India Office
Saturn Pyro India

3, Gr Floor, Eishita,
Shiv Vallabh Cross Road,
Ashokvan, Dahisar (E.),
Mumbai 400068.
+91 22284 84682
+91 98191 56654

Split Core CT (Bolt-On Type) SPD Series - 1500/5A

Previous 14 / 19 Next

Split Core CT (Bolt-On Type) SPD Series - 1500/5A eStore -  Energy Management


Download Files

SPD_Series_Split_Core_CT.pdf (229.63 KB)
The split core series current transformer has been specially designed to facilitate their installation in new or existing network. It can be installed without opening any cable or bus-bar circuit. The connection of conventional current transformers usually requires the interruption of the primary side circuit to pass cables or bus-bars through the transformer core. It can be easily opened and installed without any supply interruption thus save time and installation costs.

Application
§Energy metering & sub-metering
§Energy Management Systems
§Control & monitoring devices
§Energy saving devices

Specifications
§Rated Current: 1500A
§Secondary Output: 5A or 1A
§Accuracy: 0.5% ~ 1% from 10% to 150% of full scale range
§Rated test voltage: 3kV AC (1minute)
§Rated short-time thermal current: 60In
§Rated dynamic current, (Idyn): 2.5Ith
§Rated voltage, (Vm): 0.72kV AC
§Operating temperature: -10deg C ~ 50deg C
§Housing rating: UL 94V0
§Safety factor: FS 5

Split Core CT Dimension

Model Outer Dimension (mm) Window Size (mm) Installation Size (mm) CT Ratio Burden
L W H a e M N
SPD-XH-30x20 90 40 110 20 30 49 52 100/5 ~400/5 1VA ~ 2.5VA
SPD-XH-80x50 115 37 156 50 80 81 50 250/5 ~ 1000/5 1.5VA ~ 5VA
SPD-XH-80x80 145 37 159 80 80 111 45 250/5 ~ 1000/5 1.5VA ~ 5VA
SPD-XH-120x80 145 37 200 80 120 111 45 500/5 ~ 1500/5 2.5VA ~ 7.5VA
SPD-XH-160x80 185 53 248 80 160 118 45 1000/5 ~ 3000/5 10VA ~ 15VA

SPD Series Split Core CT


High accuracy, yet very cost effective industrial split-core and bolt-on current transformers supplier in Malaysia & Singapore. Available in Penang, KL, Selangor, Johor & anywhere in Malaysia & Singapore.