Saturn Pyro Sdn Bhd
Johor Bahru Office
44 & 44A, Jalan Palma Rafis 1,
Taman Dato Chellam,
81800 Ulu Tiram,
Johor, Malaysia.
+607-8628455
+607-8628466
enquiry@saturnpyro.com

Shah Alam Office
Block 11, No. 4-1B,
Jalan Pahat J15/J,
Kompleks Otomobile
Shah Alam Seksyen 15,
40200 Shah Alam,
Selangor, Malaysia.
+607-8628455
+607-8628466

Penang Office
Penthouse 1-21-1,
Suntech @ Penang Cybercity
Lintang Mayang Pasir 3,
11950 Bayan Baru,
Penang, Malaysia.
+607-8628455
+607-8628466
desmond@saturnpyro.com

Singapore Office
Saturn Pyro Pte Ltd

101 Kitchener Road,
#02-42 Jalan Besar Plaza,
Singapore 208511.
+607-8628455
+607-8628466
jerry@saturnpyro.com
 
India Office
Saturn Pyro India

3, Gr Floor, Eishita,
Shiv Vallabh Cross Road,
Ashokvan, Dahisar (E.),
Mumbai 400068.
+91 22284 84682
+91 98191 56654

ICx Gateway

Previous 3 / 6 Next

ICx Gateway Solutions

ICx Gateway Modules
ICx Gateway PC Based
ICx Gateway Embedded (I)
ICx Gateway Embedded (II)

ICx Gateway - Solutions for SCADA communication and protocol translation

mplementation:
  • Protocol Converter
  • Data Concentrator
  • Pass-through Configuration (Transparent Device)
  • Protocol Analyzer / Monitoring
Operating Mode:
  • Personal Computers (PC Mode): ICx Gateway can be implemented on any WINDOWS 2000 / XP based computers provided with required serial and Ethernet ports.
  • Embedded Systems:
    -     ICxE 1150: x86 Architecture
           >> Win XPE Based
           >> 2 LAN, 1 RS232, 2 RS485
           >> 2 Master, 128 Slaves
    -     ICxE 1150E: x86 Architecture
          >> Win XPE Based
          >> 2 LAN, 1 RS232, 2 RS485
          >> 2 Master, 256 Slaves
    -     ICxE 3074 / 72: Intel Pentium / Celeron
          >> Win XPE Based
          >> 2 LAN, 2 RS232, 2 RS485 (Max upto 8 LAN & 36 Serial Ports)
          >> 4 / 2 PCI Slots
          >> 8 Master, 1152 Slaves
Redundancy:
  • Device Redundancy: ICx gateway devices can be configured for redundancy allowing seamless switchover from one device to another without effecting the communication.
  • Link Redundancy: Over a single ICx gateway, communication links (Serial / Ethernet) can be configured for redundancy, eliminating single point of failure.
Protocols:
  • Full compatibility with Industrial standard Protocols.
  • Supported media types are:
    -     Serial Interface (RS 232, RS 422, RS 485)
    -     Ethernet/LAN (TCP/IP)
Database & Diagnosis:
  • Integration with MS Excel for Protocol data points and parameters definitions
  • Versioning (commented) of database allows full control.
  • Error reporting and protocol analysis enable easy maintenance of the system.
Sample Implementation :
  • Substation Gateway: ICx can communicate with SCADA System / remote devices (RTU / PLC / Transformers / IEDs) and transfer the data to Remote Control Centres.
  • Automatic / Remote Metering Device: ICx can read data from meters and communicate this data to AMR Applications.
  • IED Data Concentrator: ICx can communicate with Multiple IEDs over RS 485 and extends the full control for the Master Station over single interface for all the IEDs.
The ICx Gateway supports the following Protocols:
  • IEC 60870-5-101 Master/Slave
  • IEC 60870-5-103 Master/Slave
  • IEC 60870-5-104 Master/Slave
  • IEC 61850 Client/Server
  • DNP3 Serial Master/Slave
  • DNP3 Network Master/Slave
  • MODBUS RTU Serial Master/Slave
  • MODBUS TCP Master/Slave
  • Ethernet / IP
  • Profibus DP Master/Slave
  • HNZ Master / Slave
  • HART Master/Slave
  • Custom Protocol Support: All protocols supported are developed and maintained indigenously. RBH has experienced team and expert domain knowledge to successfully develop and deploy any customer specific protocols.
Configuration

Configurator:
  • ICx Gateways comes bundled with WINDOWS based Configuration Tool that allows easy data points (tags) configuration and mapping yet allowing full control over the application and protocol.
  • ICx allows direct integration of MS Excel sheet, enabling faster and user friendly parameter configuration (basic as well as advanced).
  • All protocol mappings and communication related parameters are comprehensively covered in Excel Sheets thus allowing complete and easy management of data points.
Database Management:
  • When Excel Datasheets are imported into ICx Gateway, new Database is created. ICx allows versioning (with user comments) of the Database
  • User can switch to any version of the database as per requirements.
Maintenance:
  • ICx Gateways has inbuilt Maintenance and Diagnosis Capabilities. It includes:
  • Protocol Analyzer: Featuring protocol packet capturing & analysis, and Error Logging
  • Gateway Start / Stop
  • Database Management: Database Downloading and Switching, Protocol selection and configuration settings
Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Messages*  
   

Switch to Mobile Version