Saturn Pyro Sdn Bhd
Johor Bahru Office
44 & 44A, Jalan Palma Rafis 1,
Taman Dato Chellam,
81800 Ulu Tiram,
Johor, Malaysia.
+607-8660510
+607-8660511
enquiry@saturnpyro.com

Shah Alam Office
K03-03-12, Tower 3,
UOA Business Park,
No 1, Jalan
Pengaturcara U1/51A,
Section U1, Kawasan
Perindustrian Temasya,
40150 Shah Alam,
Selangor, Malaysia.
+607-8660510
+607-8660511
Penang Office
Penthouse 1-21-1,
Suntech @ Penang Cybercity
Lintang Mayang Pasir 3,
11950 Bayan Baru,
Penang, Malaysia.
+607-8660510
+607-8660511
desmond@saturnpyro.com

Singapore Office
Saturn Pyro Pte Ltd

101 Kitchener Road,
#02-42 Jalan Besar Plaza,
Singapore 208511
+607-8660510
+607-8660511
jerry@saturnpyro.com
 
India Office
Saturn Pyro India

3, Gr Floor, Eishita,
Shiv Vallabh Cross Road,
Ashokvan, Dahisar (E.),
Mumbai 400068.
+91 22284 84682
+91 98191 56654

MX-3 GSM/GPRS Modbus Data Logger

Previous 14 / 22 Next

MX-3 GSM/GPRS Modbus Data Logger Data Communication


MX-3 data logger is dedicated for real time logging and analyzing of data. Using GPRS/GSM, logger sends data to re- moteusers/server.MX-3 can also communicate with other controllers and sensors.Device has wide range of optional interfaces and protocols and can read any kind of meters, controllers and sensors equipped with standard protocols. Perfect for telemetry/monitoring, control and smart metering.


Features

  • Reading data from meters (heat, water, gas, electricity...),  sensors and controllers
  • Independent data log with real time stamp (Real Time Clock)
  • Supported interfaces: M-Bus, GSM/GPRS, RS232,RS485,Data/Req
  • Up to 3 analog inputs (current, voltage, PT100 orPT1000)
  • Up to 4 discrete inputs (contact, impulse counter, alarm)
  • Remote communication and updates through GSM/GPRS
  • Galvanically isolated interfaces and power supply
  • SMS sending for alarm events
  • Batteries management. The remote monitoring devices can charge the battery and use it to power supply in the event of blackout
  • Supported protocols: Modbus RTU, Modbus TCP/IP, FTP server/cli-ent, IEC60870-5-104:2000 and others

Technical Data

Interfaces
RS232 (2 ports) distance up to 15m, speed up to 19,2 Kbit/s
RS485 (2 ports) distance up to 1,2km, speed up to 19,2 Kbit/s
Data/Req (1 port) up to 2 devices, (Kamstrup) data trans- fer interface
M-Bus (1 port) up to 8 M-Bus devices
GSM/GPRS 4 band 850/900/1800/1900 MHz
Discrete IN 4 sink contacts
Analog IN 3 current 0/4-20mA, voltage 0-10V, thermoresistor PT100 or PT1000
Protocols
Modbus RTU, Modbus TCP/IP, UDP, ARP, SNTP, DynDNS, FTP server/ client, DNS client, IEC60870-5-104:2000 (IEC 104)
Climate conditions
Operating temperature -30 .. +60oC
Storage temperature -40 .. +60oC
Humidity range 5-95%, non-condensing

General
Power supply 15-36 VDC
Galvanic isolation >1000V
Capacity <5VA
Internal battery 3,7V 500 mAh
CPU ARM7
Memory archive storage up to 8 MB, data storage without power 5 years
Physical characteristics
Dimensions 107x128x50 mm
Weight 275 g
IP protection IP20
LED indication
Status of discrete input, for each port
Serial ports read/write for each port
GSM/GPRS modem status
Other features
Real time clock
M-Bus auto setup


MX-3 data logger / gateway is suitable for data acquisition from any kind of meters using standard protocols. Our R&D department also can adjust our device to read meters via non-standard protocols.

MX-3 can read Kamstrup,  Sensus, Diehl, Danfoss,  Itron, Landis & Gyr,  Apator and other meters (like exotic meters, in- dustrial meters).

MX-3 can also work as controller/controll unit and even control /read other controllers, like Danfoss ECL 300.






MX-3 GSM/GPRS Data Logger Application