Split Core CT (Bolt-On Type)
SPD Series - 1200/5A, Class 1
The split core series current transformer has been specially designed to facilitate their installation in new or existing network. It can be installed without opening any cable or bus-bar circuit. The connection of conventional current transformers usually requires the interruption of the primary side circuit to pass cables or bus-bars through the transformer core. It can be easily opened and installed without any supply interruption thus save time and installation costs.
Application
§Energy metering & sub-metering
§Energy Management Systems
§Control & monitoring devices
§Energy saving devices
Specifications
§Rated Current: 1200A
§Secondary Output: 5A or 1A
§Accuracy: 0.5% ~ 1% from 10% to 150% of full scale range
§Rated test voltage: 3kV AC (1minute)
§Rated short-time thermal current: 60In
§Rated dynamic current, (Idyn): 2.5Ith
§Rated voltage, (Vm): 0.72kV AC
§Operating temperature: -10deg C ~ 50deg C
§Housing rating: UL 94V0
§Safety factor: FS 5
Model | Outer Dimension (mm) | Window Size (mm) | Installation Size (mm) | CT Ratio | Burden | ||||
L | W | H | a | e | M | N | |||
SPD-XH-30x20 | 90 | 40 | 110 | 20 | 30 | 49 | 52 | 100/5 ~400/5 | 1VA ~ 2.5VA |
SPD-XH-80x50 | 115 | 37 | 156 | 50 | 80 | 81 | 50 | 250/5 ~ 1000/5 | 1.5VA ~ 5VA |
SPD-XH-80x80 | 145 | 37 | 159 | 80 | 80 | 111 | 45 | 250/5 ~ 1000/5 | 1.5VA ~ 5VA |
SPD-XH-120x80 | 145 | 37 | 200 | 80 | 120 | 111 | 45 | 500/5 ~ 1500/5 | 2.5VA ~ 7.5VA |
SPD-XH-160x80 | 185 | 53 | 248 | 80 | 160 | 118 | 45 | 1000/5 ~ 3000/5 | 10VA ~ 15VA |
High accuracy, yet very cost effective industrial split-core and bolt-on current transformers supplier in Malaysia & Singapore. Available in Penang, KL, Selangor, Johor & anywhere in Malaysia & Singapore.
Available in Penang, KL, Selangor, Johor & anywhere in Malaysia & Singapore.
Saturn Pyro provides reliable engineering services such Electrical Safety Survey, Power System Studies (Short Circuit, Load Flow & Protection Discrimination on ETAP), Arc Flash Assessment & Labeling, Design Of Earthing & Lightning Protection, Measurement Of Touch & Step potentials, Power Quality Management, Energy Audit and Data Center Performance Assessment. We also provides Electrical Safety Survey such as Inspection of an electrical installation, Identification of risk (electrical hazards), Review of documentation, operations & maintenance procedures, contingency planning, Generation of report in details of risk potentials and plan for mitigation, Closing report post implementationas. Available in Pulau Pinang, Johor, Kuala Lumpur (KL), Selangor and anywhere in Malaysia / Singapore / Bangalore / India / Mumbai.
Inquiry - Split Core CT (Bolt-On Type) SPD Series - 1200/5A, Class 1