QI-HSC Split Core Hall's Effect
QI-HSC Split Core Hall's Effect

Share:


QI-HSC Split Core Hall's Effect

QI-HSC

Split Core Hall's Effect

AC/DC CURRENT TRANSFORMER


QI-HSC-50 / QI-HSC-100
NOMINAL CURRENT MEASUREMENT
QI-HSC-50 : 50 A AC/DC
QI-HSC-100: 100 A AC/DC
AUXILIARY POWER SUPPLY ± 12 … 15 V dc
WORKING FREQUENCY From DC up to 20 kHz
LOAD RESISTANCE Min 10 kOhm
ABSORPTION @ 15 V dc 25mA
VOLTAGE OUTPUT @ Nominal current Ip = 0 ± 25 mV
VOLTAGE OUTPUT @ Nominal current Ipn ± 4 V ±1%
ACCURACY +/- 1%
LINEARITY < 1%
THERMAL DRIFT ± 1 mV/°C
RESPONSE TIME 0...90% 10 µs
ISOLATION PRIMARY/SECONDARY 3 kV
WORKING TEMPERATURE -25°C...85°C
STORAGE TEMPERATURE -40°C...100°C
CONNECTION Removable Connector for cable section 0,2 ÷ 2,5 mm2
WEIGHT 80 gr


Ip: Primary Current
Ipn: Nominal Primary Current
0V: measurement reference and auxiliary power supply
V+: Positive auxiliary power supply +12…15V
V-: Negative auxiliary power supply -12…15V
Vout: Nominal output ±4 V



High accuracy, yet very cost effective split-core hall's effect AC/DC current transformers supplier in Malaysia & Singapore. Available in Penang, KL, Selangor, Johor & anywhere in Malaysia & Singapore.

Available in Penang, KL, Selangor, Johor & anywhere in Malaysia & Singapore.


Saturn Pyro provides reliable engineering services such Electrical Safety Survey, Power System Studies (Short Circuit, Load Flow & Protection Discrimination on ETAP), Arc Flash Assessment & Labeling, Design Of Earthing & Lightning Protection, Measurement Of Touch & Step potentials, Power Quality Management, Energy Audit and Data Center Performance Assessment. We also provides Electrical Safety Survey such as Inspection of an electrical installation, Identification of risk (electrical hazards), Review of documentation, operations & maintenance procedures, contingency planning, Generation of report in details of risk potentials and plan for mitigation, Closing report post implementationas. Available in Pulau Pinang, Johor, Kuala Lumpur (KL), Selangor and anywhere in Malaysia / Singapore / Bangalore / India / Mumbai.

 
 
Saturn Pyro menyediakan perkhidmatan kejuruteraan yang boleh dipercayai seperti Tinjauan Keselamatan Elektrik, Kajian Sistem Kuasa (Litar Pintas, Diskriminasi Aliran Beban & Perlindungan pada ETAP), Penilaian & Pelabelan Denyar Arka, Reka Bentuk Pembumian & Perlindungan Kilat, Pengukuran potensi Sentuhan & Langkah, Pengurusan Kualiti Kuasa , Audit Tenaga dan Penilaian Prestasi Pusat Data. Kami juga menyediakan Tinjauan Keselamatan Elektrik seperti Pemeriksaan pemasangan elektrik, Pengenalpastian risiko (bahaya elektrik), Semakan dokumentasi, prosedur operasi & penyelenggaraan, perancangan kontingensi, Penjanaan laporan dalam butiran potensi risiko dan rancangan untuk mitigasi, Pos laporan penutup perlaksanaan. Available in Pulau Pinang, Johor, Kuala Lumpur (KL), Selangor and anywhere in Malaysia / Singapore / Bangalore / India / Mumbai.